Skip to main content
Figure 6 | Journal of NeuroEngineering and Rehabilitation

Figure 6

From: Time-division multiplexing for myoelectric closed-loop control using electrotactile feedback

Figure 6

Average results (mean ± standard error) across conditions: a) root mean square tracking error and b) overshoot between the reference and generated trajectory. Horizontal bar with asterisks indicates the statistically significant difference between the respective conditions. Asterisks only indicate that a group is statistically significantly different from all the other conditions. Notation: CONT-CLT – continuous feedback, TDM40, TDM100, TDM300 – time–division multiplexing (TDM) with 40 ms, 100 ms, and 300 ms feedback window length. (*, p < 0.05; **, p < 0.01; ***, p < 0.001).

Back to article page