From: Upper extremity asymmetry due to nerve injuries or central neurologic conditions: a scoping review
Categories | Tests and sensors used in the articles | Instances | Type of test | Articles |
---|---|---|---|---|
Activity Monitoring (ActM) | Triaxial Accelerometry | 14 | Objective | [174, 175, 180, 201, 213, 222, 223, 229, 240, 250, 254, 269, 273, 276, 281] |
Uniaxial Accelerometry | 9 | Objective | ||
Upper Limb Activity Monitor (Accelerometry) | 1 | Objective | [233] | |
Amount of Use Tests (AoUT) | Actual amount of use test | 1 | Subjective | [278] |
Motor Activity Log | 7 | Subjective | ||
Disability Measures (DM) | Arm Motor Ability Test | 1 | Mixed | |
Disabilities of Arm, Shoulder, and Hand | 2 | Subjective | ||
Expanded Disability Status Scale | 2 | Subjective | ||
Fugl-Meyer Assessment | 14 | Objective | [230, 234, 237, 242, 249, 250, 254, 258, 259, 265, 267, 268, 271, 279] | |
Functional Independence Test | 1 | Subjective | [252] | |
modified Rankin Scale | 1 | Subjective | [269] | |
Fine and Gross Motor Tests (FGMT) | Bruininks–Oseretsky Test of Motor Proficiency | 1 | Mixed | [179] |
custom reaching task | 3 | Objective | ||
Distractor test | 1 | Objective | [227] | |
Jebsen–Taylor Test of Hand Function | 6 | Objective | ||
Fine Motor Tests (FMT) | Action Reaction Arm Test | 6 | Objective | |
Computerized Peg Moving Test | 1 | Objective | [176] | |
Aiming-Tapping Task | 1 | Objective | [183] | |
Melbourne Assessment | 2 | Subjective | ||
Nine-Hole Peg Test | 9 | Objective | ||
Grooved Pegboard Test | 1 | Objective | [259] | |
Wolf Motor Function Test | 6 | Mixed | ||
Gross Motor Tests (GMT) | Assisting Hand Assessment | 7 | Subjective | |
Box and Block test | 9 | Objective | ||
Caregiver Functional Use Survey | 1 | Subjective | [179] | |
Custom coordination tests | 8 | Objective | ||
Manual Ability Classification System | 2 | Subjective | ||
Handedness Tests (HT) | Edinburgh handedness inventory | 5 | Subjective | |
Kinematics Tests (KT) | Electrogoniometer | 6 | Objective | |
Electromagnetic Motion Tracking | 10 | Objective | [173, 187, 195, 228, 247, 248, 263, 273, 274, 282 | |
Inertial Measurement Unit | 4 | Objective | ||
Optical Motion Capture | 17 | Objective | [18, 178, 182, 186, 188, 192, 196,197,198, 206, 209, 216,217,218, 235, 264, 266] | |
Motion Reflex Test (MRT) | modified Traffic Light paradigm | 1 | Objective | [219] |
Myography (MG) | Electromyography | 11 | Objective | |
Mechanomyography | 2 | Objective | ||
 | 36 item Short Form survey | 1 | Subjective | [174] |
Quality of Life Surveys (QOL) | World Health Organization Quality of Life | 1 | Subjective | [174] |
Stroke Impact Scale | 3 | Subjective | ||
Unified Parkinson's Disease Rating Scale | 4 | Subjective | ||
Spasticity Tests (ST) | Modified Ashworth Scale | 8 | Subjective | |
Strength Measures (SM) | Force Transducer based tests | 33 | Objective | [186, 193,194,195, 202, 207, 220, 221, 236, 237, 239, 242,243,244, 247, 249, 251,252,253, 256,257,258,259,260, 263,264,265, 267, 268, 274, 282] |
Graded redefined assessment of strength, sensibility and prehension | 1 | Mixed | [215] | |
Motricity Index | 2 | Mixed |