Table 2 ANOVA test for embodiment metrics

From: Experimental evaluation of the impact of sEMG interfaces in enhancing embodiment of virtual myoelectric prostheses

Variable

Sensors

Delay

Sensors \(\times\) Delay

VPE

p = 1.0, F < 0.0001

p = 1.0, F < 0.01

p = 1.0, F < 0.01

Embodiment

p \(=\) 0.012, F = 6.38

p = 0.139, F = 2.19

p = 0.048, F = 3.9

Ownership

p \(=\) 0.016, F = 5.86

p = 0.571, F = 0.32

p = 0.692, F = 0.16

Location

p \(=\) 0.736, F = 0.11

p = 0.06, F = 3.56

p = 0.072, F = 3.28

Agency

p \(=\) 0.064, F = 3.48

p = 0.679, F = 0.17

p = 0.0612, F = 3.55