Skip to main content

Table 3 Sensitivity (%) and specificity (%) for each class recorded from distal end (EXP1) and proximal end (EXP2) from able-bodied all subjects using WMD method

From: Towards identification of finger flexions using single channel surface electromyography – able bodied and amputee subjects

Class

Distal end (EXP 1)

Proximal end (EXP 2)

Sensitivity mean (±SD)%

Specificity mean (±SD)%

Sensitivity mean (±SD)%

Specificity mean (±SD)%

Class 1

92 (±0.05)

98 (±0.02)

94 (±0.07)

98 (±0.02)

Class 2

95 (±0.06)

97 (±0.03)

95 (±0.04)

98 (±0.01)

Class 3

92 (±0.06)

98 (±0.03)

91 (±0.05)

96 (±0.02)

Class 4

93 (±0.06)

98 (±0.02)

90 (±0.06)

97 (±0.03)

Overall mean (±SD)

93 (±0.01)

98 (±0.01)

93 (±0.02)

97 (±0.01)