Skip to main content

Table 2 Summary of reliability results of each ‘whole-foot’ for the three walking trajectories and for the four output variables

From: Test-retest reliability of an insole plantar pressure system to assess gait along linear and curved trajectories

 

Left

Right

 

ICC

CI 95%

% Err

MDC95

ICC

CI 95%

% Err

MDC95

Linear trajectory

 

Peak Force

0.96

(0.94-0.97)

4.16

82.71 (N)

0.96

(0.93-0.97)

4.28

85.39 (N)

Peak Pressure

0.95

(0.93-0.97)

6.73

4.23 (kPa)

0.95

(0.93-0.97)

3.81

3.11 (kPa)

Contact Area

0.96

(0.94-0.98)

4.92

9.38 (cm2)

0.96

(0.94-0.98)

4.64

10.38 (cm2)

Stance

0.81

(0.62-0.89)

4.62

0.05 (s)

0.87

(0.80-0.92)

3.41

0.04 (s)

Clockwise trajectory

 

Peak Force

0.97

(0.95-0.99)

4.47

67.84 (N)

0.97

(0.95-0.98)

3.60

68.87 (N)

Peak Pressure

0.97

(0.93-0.98)

8.75

3.00 (kPa)

0.95

(0.91-0.97)

6.78

4.3 (kPa)

Contact Area

0.99

(0.98-1.00)

3.76

5.07 (cm2)

0.99

(0.98-1.00)

2.95

5.63 (cm2)

Stance

0.93

(0.89-0.95)

4.43

0.05 (s)

0.92

(0.87-0.95)

3.47

0.06 (s)

Counterclockwise trajectory

 

Peak Force

0.97

(0.95-0.99)

4.65

66.56 (N)

0.97

(0.96-0.98)

4.33

66.21 (N)

Peak Pressure

0.96

(0.93-0.98)

5.59

3.37 (kPa)

0.94

(0.87-0.97)

10.14

3.2 (kPa)

Contact Area

0.99

(0.97-0.99)

3.95

5.23 (cm2)

0.99

(0.97-1.00)

3.50

5.29 (cm2)

Stance

0.93

(0.88-0.96)

4.46

0.05 (s)

0.91

(0.85-0.94)

4.86

0.05 (s)

  1. ICC, intraclass correlation coefficient; CI 95%, 95% Confidence Interval of ICC; % Err, percentage mean error between values of the first and the second day of acquisition; MDC95, minimum detectable change at the 95% confidence level.