Skip to main content

Table 2 Mean (SD) values of test-retest parameters

From: Multi-finger coordination in healthy subjects and stroke patients: a mathematical modelling approach

 

Hand opening

Hand closing

 

c1

c2

c3

c4

c1

c2

c3

c4

ICC2,1

0.96

(0.03)

0.88

(0.07)

0.78

(0.06)

0.79

(0.07)

0.96

(0.03)

0.89

(0.04)

0.86

(0.03)

0.84

(0.07)

σw

4.5°

(1.4°)

3.8°

(1.4°)

6.7%Dur

(2.1%Dur)

7.0%Dur

(3.1%Dur)

4.3°

(1.1°)

5.0°

(1.9°)

3.5%Dur

(2.0%Dur)

7.1%Dur

(2.4%Dur)

σr/σw%

90.8

(4.8)

93.3

(5.9)

98.0

(3.5)

97.6

(4.0)

94.3

(5.6)

99.7

(0.6)

93.4

(5.9)

98.6

(2.0)

Mean test-retest error

2.5°

(1.6°)

2.7°

(1.9°)

3.6%Dur

(2.6%Dur)

2.7%Dur

(2.5%Dur)

3.1°

(1.9°)

2.8°

(2.2°)

3.4%Dur

(2.4%Dur)

3.1%Dur

(2.9%Dur)

Max. test-retest error

5.7°

6.5°

8.8%Dur

7.7%Dur

6.9°

7.2°

8.2%Dur

9.0%Dur

  1. ICC2,1: Intraclass Correlation Coefficient, model 2,1
  2. σw: within-subject standard deviation
  3. σr/σw%: percentage ratio between intra-session standard deviation and within-subject standard deviation