Skip to main content

Table 2 Characteristics of the tested systems

From: Comparison of eye tracking, electrooculography and an auditory brain-computer interface for binary communication: a case study with a participant in the locked-in state

 

EOG

Eye Tracker

BCI

Allows communication independent of the caregiver

yes

yes

yes

Enables muscle-independent communication

no

no

yes

Speed of communication

medium

fastest

slowest

Commercially available

   

• Hardware

yes

yes

yes

• AT software and support

no

yes

no

Costs

medium

lowest

highest

Burden on the caregiver

medium

lowest

highest

Applications

communication

communication

communication (binary)