From: Standardizing fatigue-resistance testing during electrical stimulation of paralysed human quadriceps muscles, a practical approach
Electrode Configuration
CONV1
POS2
POS3
POS4
CONV2
Normalized Initial peak Torque
% of MEC
41.6 ± 2.7
39.1 ± 4.7
36.7 ± 2.9
39.4 ± 1.5
39.1 ± 2.7
Intensity at 40% MEC
mA
70.3 ± 10.1
59.7* ± 3.3
50.2* ± 4.0
53.2* ± 5.3
66.8 ± 5.4