Skip to main content

Table 13 FOG detection: One-freezer-held-out cross validation for the 3-layer LSTM model with and without most frequent freezer

From: Prediction and detection of freezing of gait in Parkinson’s disease from plantar pressure data using long short-term memory neural-networks

  With P07’s data in training set Without P07’s data in training set
Held out participant Sensitivity (%) Specificity (%) Sensitivity (%) Specificity (%)
1 83.6 86.3 71.3 93.1
2 83.5 90.1 63.8 91.4
3 71.7 92.0 60.1 94.3
6 86.9 90.7 78.1 92.8
8 87.6 74.7 88.2 79.5
9 93.6 88.6 99.7 86.8
Mean ± SD 84.5 ± 6.6 87.1 ± 5.8 76.9 ± 13.7 89.7 ± 5.1