Skip to main content

Table 2 Intra rater reliability of various parameters for 10 repetitive meaurments

From: Quantitative measurement of resistance force and subsequent attenuation during passive isokinetic extension of the wrist in patients with mild to moderate spasticity after stroke

Parameters

ICC (1,1)(95%CI)

ICC(1,10)(95%CI)

30 deg/s

60 deg/s

90 deg/s

30 deg/s

60 deg/s

90 deg/s

Maximum RF

0.995 (0.990–0.998)

0.995 (0.990–0.998)

0.993 (0.987–0.997)

0.9995 (0.9990–0.9998)

0.999 (0.9990–0.9998)

0.9993 (0.9987–0.9997)

Damping force

0.797 (0.670–0.904)

0.895 (0.816–0.953)

0.848 (0.744–0.931)

0.975 (0.953–0.990)

0.988 (0.978–0.995)

0.982 (0.967–0.993)

(Total) damping impulse

0.974 (0.952–0.989)

0.972 (0.948–0.988)

0.970 (0.945–0.987)

0.997 (0.995–0.999)

0.997 (0.995–0.999)

0.997 (0.994–0.999)

(Pure) damping impulse

0.685 (0.525–0.841)

0.823 (0.706–0.917)

0.813 (0.692–0.912)

0.956 (0.917–0.981)

0.979 (0.960–0.991)

0.977 (0.957–0.991)

Damping force ratio

0.557 (0.382–0.757)

0.621 (0.451–0.801)

0.754 (0.612–0.881)

0.926 (0.861–0.969)

0.941 (0.891–0.976)

0.968 (0.940–0.987)

Damping impulse ratio

0.480 (0.306–0.699)

0.391 (0.227–0.624)

0.629 (0.459–0.806)

0.902 (0.815–0.959)

0.865 (0.746–0.943)

0.944 (0.895–0.976)