Skip to main content

Table 1 Performance of the proposed mouth opening detection algorithm

From: Infrared thermography as an access pathway for individuals with severe motor impairments

Participant

Video length (sec)

Total Video frames

Actual # of mouth openings

Sensitivity

Specificity

1

256

7662

50

88%

100%

2

252

7546

50

96%

100%

3

254

7621

50

96%

100%

4

252

7481

50

98%

100%

5

244

7424

50

88%

99%

6

243

7594

50

92%

98%

7

245

7664

50

94%

99%

8

243

7613

50

80%

100%

9*

153

4592

30

93%

99%

10*

272

8160

15

60%

99%

  1. *Participant with severe disability.