Skip to main content

Table 2 Electrode-frequency pairs used during the online intervention

From: On the design of EEG-based movement decoders for completely paralyzed stroke patients

Pat. #

Group

Channel

Frequency

1

Exp.

P7

11.5–14.5

2

C4, P4, P8

8.5–11.5

3

C4, P4, P8

8.5–11.5

4

C4, P4, P8

8.5–11.5

5

P7

5.5–8.5

6

C4, P4

14.5–17.5

7

C4, P8

17.5–20.5

8

C3

11.5–14.5

9

C4

5.5–8.5

10

C3, P3, P7

8.5–11.5

11

C3

5.5–8.5

12

C3

5.5–8.5

13

P7

5.5–8.5

14

C4, P4, P8

8.5–11.5

15

C4

5.5–8.5

16

P7

5.5–8.5

33

C-

F4, C4, P8

14.5–17.5

34

F4, C4, P8

17.5–20.5

35

F4, C4, P4, P8

20.5–23.5

36

C4, P4, P8

8.5–11.5

37

C4, P8

9.5–12.5

  1. Group indicates if the patient performed the Experimental—contingent positive condition (Exp), or the contingent negative condition (C-). Patients from the sham group are excluded from this table since they did not receive closed-loop feedback. Channel and frequency correspond to the electrodes and frequencies used to provide contingent feedback during the intervention