Skip to main content

Table 3 Influence of lesion side and consciousness on MI

From: Neural coding of autonomic functions in different states of consciousness

2-way ANOVA

Source

F

p-value

Fp1

Side

4.212

0.045

Consciousness

9.168

0.004

Side*Consciousness

2.267

0.138

Fp2

Side

14.429

< 0.001

Consciousness

2.205

0.143

Side*Consciousness

0.152

0.698

F7

Side

5.874

0.021

Consciousness

4.152

0.046

Side*Consciousness

0.251

0.618

F3

Side

6.201

0.013

Consciousness

5.312

0.025

Side*Consciousness

1.005

0.320

F4

Side

18.151

< 0.001

Consciousness

4.824

0.032

Side*Consciousness

0.065

0.799

F8

Side

12.177

0.001

Consciousness

1.958

0.167

Side*Consciousness

0.118

0.733

T3

Side

4.144

0.047

Consciousness

3.189

0.080

Side*Consciousness

1.011

0.319

C3

Side

4.162

0.046

Consciousness

4.570

0.037

Side*Consciousness

1.970

0.166

C4

Side

20.306

 < 0.001

Consciousness

6.751

0.012

Side*Consciousness

0.166

0.685

T4

Side

14.557

< 0.001

Consciousness

2.580

0.114

Side*Consciousness

0.089

0.766

T5

Side

3.935

0.054

Consciousness

5.090

0.028

Side*Consciousness

0.710

0.403

P3

Side

3.362

0.081

Consciousness

4.412

0.040

Side*Consciousness

1.614

0.209

P4

Side

13.191

0.001

Consciousness

6.772

0.012

Side*Consciousness

0.484

0.490

T6

Side

13.603

0.001

Consciousness

4.601

0.036

Side*Consciousness

0.527

0.471

  1. Results on secondary analysis on hemorrhagic patients only. UWS, MCS − and MCS +, e-MCS patients are respectively grouped together. For each electrode a 2-way ANOVA was performed with the main effects represented by side (left versus right) and consciousness (EMCS/MCS + versus MCS − /UWS). Variable in bold were considered significant